Contrex M-Traverse Uživatelský manuál Strana 65

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 202
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 64
3 - 18
Dwell (CP-10)
The Dwell (CP-10) parameter allows the Follower mechanism to pause
at the end of the Follower profile before ramping back in the opposite
direction. In level wind applications, this parameter is a portion of the
encoder lines in one rotation of the reel (Lead). In web scanning
applications, this parameter is a portion of the encoder lines in one
traverse length. The Dwell parameter does not need to be an exact
number, the system will perform adequately with a close estimate .
The factory default for the Dwell Control Parameter is found in Table 3-12. To modify
the default parameter refer to Table 3-13. If you are uncertain how to enter a Control
Parameter, review the
Operations: Keypad
section.
Table 3-12 Default Dwell Control Parameter
CP Parameter Name Parameter Value
CP-10 Dwell 0
Table 3-13 Entering Dwell Control Parameter
CP Parameter Name Parameter Value
CP-10 Dwell In a level wind applications, enter a portion of the
encoder lines in one rotation of the reel
In a web scanning applications, enter a portion of the
encoder lines in one traverse length.