C - 13
CP-73 CONTROL MASK
The Serial Communications can control some of the logic input functions. Enter the number for
the required functions in Control Mask (CP-73), as listed below.
0 = F–Stop only
1 = F–Stop, Run, R–Stop
2 = F–Stop, Master/Follower, Setpoint Select
3 = All of the above
CP-74 DRIVE ENABLE LOGIC
Drive Enable Logic (CP-74) determines which conditions of the Ramped Reference (MP-46) and
the feedback will control the Drive Enable digital output.
Enter "0" to deactivate the Drive Enable digital output (output high) when the Ramped
Reference is zero, and activate the Drive Enable digital output (output low) when
the Ramped Reference is not zero.
Enter "1" to deactivate the Drive Enable digital output when both the Ramped
Reference and the feedback are zero, and activate the Drive Enable digital
output when the Ramped Reference is not zero.